Fixed wire testing and EICRs in Milton Keynes
Inspection and testing for industrial and commercial premises in Milton Keynes and across the UK.
Request a testing quoteInspecting your permanent electrical installation
Fixed wire testing assesses the condition of your building’s permanent electrical installation, including wiring, distribution boards and protective devices. The findings are recorded in an Electrical Installation Condition Report (EICR), with the agreed extent and any limitations stated. Inspection and testing identifies defects and assesses suitability for continued service using BS 7671 as the benchmark.
Why it matters
The Electricity at Work Regulations 1989 require electrical systems to be maintained so as to prevent danger, so far as is reasonably practicable. Periodic inspection and testing supports that duty by identifying deterioration and defects and recording the action required. Reports also help you plan maintenance and respond to an insurer’s requirements.
How often do you need it?
Common initial recommendations are three years for industrial premises and five years for commercial premises. The appropriate interval depends on the installation’s condition, use, environment and maintenance history. Your inspector recommends the next inspection date, taking previous findings into account. Significant changes or deterioration may call for an earlier assessment.
What we test
- Distribution boards, switchgear and submains
- Insulation resistance, continuity and earth fault loop impedance
- RCD operation and assessment of protective devices
- Earthing and bonding
- Lighting, small power and fixed supplies to machinery
The extent and test methods are agreed for your installation, with sensitive equipment and operational constraints considered before testing.
How we work
- Survey and scoping. We agree the extent of inspection and testing, access requirements and critical circuits.
- Planned isolations. We schedule the work with your site team, including out-of-hours testing where required.
- Inspection and testing. Qualified engineers inspect and test the installation using suitable, calibrated equipment.
- Report. You receive an EICR with observations classified C1 (danger present), C2 (potentially dangerous), C3 (improvement recommended) or FI (further investigation required without delay), where applicable.
- Remedial works. We explain the findings and can quote for repairs, with one point of contact for testing and remedial work.
Who we test for
Factories and manufacturing sites, warehouses, offices, retail and leisure venues, schools and education sites, and landlords or facilities managers with multi-site portfolios.
Why choose MWG?
- NAPIT registered, ECA member and CHAS accredited
- Experience working in occupied premises, including electrical installation work at Volkswagen UK in Milton Keynes
- Testing, remedial works and planned maintenance from one team
Electrical distribution work at Volkswagen UK

Frequently asked questions
What is the difference between an EICR and fixed wire testing?
Fixed wire testing is the common term for periodic inspection and testing of a permanent electrical installation. The EICR is the report that records the findings.
Will testing shut down our site?
Some tests require circuits to be isolated. We agree a programme with your site team, using sectional isolations and out-of-hours work where appropriate to minimise disruption.
What happens if the report is unsatisfactory?
We explain the observations and the action needed. Immediate danger requires immediate action, potentially including isolation. We can quote for remedial works and provide the relevant certification when those works are complete.
Do you cover areas outside Milton Keynes?
Yes. We carry out industrial and commercial work across the UK.